3.5.5 Fitting the connector for incoming mains
General
This section describes how to manufacture a cable for connecting the main power
to the controller.
Detailed view
xx2100001257
Description
Cable glandA
O-ringB
Hood, EMCC
Locking lever (x2)D
Connector insertE
Specifications
The following describes the cable requirements for the incoming mains connection
to the OmniCore V250XT Type B controller.
DescriptionComponent
Flexible oil resistant rubberCable type
3G x 6 mm
2
or AWG10Cable area
PE1 and PE2 points on X0 (incoming mains connector).Protective earth
Included parts
The following parts are included in the delivery.
QuantityOrder numberPart
13HAC075871-001Connector kit
Continues on next page
82 Product manual - OmniCore V250XT Type B