5.3.2.1 Replacing the motor connector
Removing the motor connector
Preparations
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Opening the door on page 184.Open the door.2
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
3
xx2200001817
Removing the motor connector
Note/IllustrationAction
Disconnect all connectors from the unit
to be replaced.
1
Continues on next page