3.5.8 Ethernet networks on OmniCore
Network segment overview
The Ethernet networks used by OmniCore are distributed into the following
segments:
UsageController portsNetwork segment
Process equipment local to this specific robot.DEVPrivate Network
ABB service personnel in close proximity to the
controller, with a single client connected to the
controller.
Note
The management port shall never be used for
more than one client at a time. ABB Robotics
assumes no responsibility for any errors/hazards
that may appear when more than one client is
used.
MGMT (Management)
FlexPendant connection.TPU
ABB Connect connection.ABB ConnectABB Connect Network
Public/factory network.WAN 1Public Network
Intended for connecting the robot controller to a
factory wide industrial network.
WAN 2
Intended for connecting the robot controller to a
factory wide industrial network isolated from
WAN.
LANI/O Network
Product manual - OmniCore V250XT Type B 91
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
3 Installation and commissioning
3.5.8 Ethernet networks on OmniCore