Note/IllustrationAction
xx1900002446
Push the buckle of the digital base
slightly and take out the digital base.
2
xx1900002447
Refitting the digital base (option)
Refitting the digital base (option)
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Continues on next page
Product manual - OmniCore V250XT Type B 227
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
5 Repair
5.2.6 Replacing the scalable I/O unit
Continued