Note/IllustrationAction
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
3
xx2200001817
Removing the power unit
Note/IllustrationAction
Disconnect all connectors from the unit
to be replaced.
1
xx2300001492
Remove the screws and pull the power
unit out from the two guiding pins on the
mounting plate.
CAUTION
Only the sheet metal on the power unit
can be used for holding.
Do not touch the connectors or the filter
on the power unit.
2