Refitting the drive unit
Refitting the drive unit
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
2
xx2200001817
Screws: Torx pan head screw M4x8 (4 pcs)Position the drive unit on the lower guid-
ing pin on the mounting plate, and then
tip the unit upwards against the upper
guiding pin. Secure the screws.
3
Tightening torque: 2 Nm
xx2100000338