EasyManua.ls Logo

ABB OmniCore V250XT Type B - Page 301

ABB OmniCore V250XT Type B
468 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Note/IllustrationAction
Screws: Torx, countersunk screw M4x10 (4
pcs)
Insert the HMI signal connector into the
cover from inside the cabinet.
3
Tightening torque: 1.7 Nm±10%.Secure it with the screws.
xx2100000832
Reconnect any connectors disconnected
at removal.
4
Secure the cables on HMI signal connect-
or with new cable ties.
Tip
Use the same position as from removing
the HMI signal connector.
5
xx2100000831
Refit the cover plate.6
Continues on next page
Product manual - OmniCore V250XT Type B 301
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
5 Repair
5.3.3 Replacing the HMI signal (FlexPendant) connector
Continued

Table of Contents

Related product manuals