LEDs
The illustration below shows the indication LEDs on the drive unit.
E
A B C D
xx2100001069
DescriptionName
The status indicator LED can be used to
identify the following status during star-
tup/power on:
Red, steady: Default when power is
available.
Red, flashing (~1Hz): Power is on, self-
test is ongoing, operating system is
loading.
Green, flashing (~1Hz): Application is
loaded and waiting for communication.
Green, steady: Drive unit is operation-
al.
If the LED does not turn steady green after
30-60 sec, the status indicator LED can be
used to identify the following issues:
No color: Power to the drive unit is
missing.
Red, steady: Internal error.
Red, flashing (~1Hz): Firmware error
or self-test failure.
Green, flashing (~1Hz): Communica-
tion error to another module.
MS (Module Status) LEDA
Continues on next page
Product manual - OmniCore V250XT Type B 371
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
7 Troubleshooting
7.3.3 Troubleshooting the drive unit
Continued

Table of Contents