EasyManua.ls Logo

ABB OmniCore V250XT Type B - Page 385

ABB OmniCore V250XT Type B
468 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DescriptionName
The Module status LED indicates the follow-
ing:
No color: AC_IN is missing or
24V_TRUNK is not available.
Red, flashing: Performing self test.
Red, steady: An error has occurred
and unit is in error state.
Green, flashing: Unit is waiting for
24V_SYS and internal communication.
Green, steady: Unit is in operational
state. Activating CTRL inputs in this
state will charge DC_OUT.
MODULE STATUSB
The EtherCAT Device State LED/RUN LED
displays the actual state of the device state
machine. The run state is as follows:
Off: Power unit is in state INIT.
Green flashing (slow): Power unit is in
state PRE-OPERATIONAL.
Green single flash: Power unit is in
state SAFE-OPERATIONAL.
Green steady: Power unit is in state
OPERATIONAL.
Green flickering (fast): Power unit is
in state BOOTSTRAP.
ECAT STATUSC
Shows the network communication speed.
Green steady: Speed is 100 Mbps.
Off: Speed is 10 Mbps.
SPEEDD
Shows the Link activity of the EtherCAT slave
port 1.
Off: No link
Yellow flashing: Link and activity.
Yellow steady: Link without activity.
LINK/ACTE
Shows the network communication speed.
Green steady: Speed is 100 Mbps.
Off: Speed is 10 Mbps.
SPEEDF
Shows the Link activity of the EtherCAT slave
port 0.
Off: No link
Yellow flashing: Link and activity.
Yellow steady: Link without activity.
LINK/ACTG
Required test equipment
Equipment needed for troubleshooting:
NoteEquipment
Multimeter
Insulating gloves
3HAC074000-008Circuit diagram - OmniCore V250XT, rev 04
or later
Continues on next page
Product manual - OmniCore V250XT Type B 385
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
7 Troubleshooting
7.3.5 Troubleshooting the power unit
Continued

Table of Contents

Related product manuals