Safety board front panel connectors
xx2300000501
CAUTION
Safety functions must be verified before use. Safety functions must be tested
regularly.
Connector X13
Description
Connector for HMI signalsConnection
Dynamic D-2100DType
Tyco Electronics
1376137-1Article number
NamePinNamePin
ENABLE_CH1B124V_CH1_HMIA1
0V_IO_HMIB2HMI_ESTOP_CH1A2
ENABLE_CH2B3HMI_ESTOP_CH2A3
24V_CH2_HMIB40V_IO_HMIA4
0V_TPUB524V_TPUA5
24V_MONB6MON_LAMPA6
24V_MONB7MON_PBA7
-B8-A8
-B9-A9
-B10-A10
Connector X14
Description
Connector for Safety IO signalsConnection
S2L 3.50 90FType
Weidmüller
1728680000Article number
The connector X14 allows for connecting general stop and emergency stop devices.
General Stop is operational in both manual mode and automatic mode. See
Protective stop and emergency stop on page 21.