EasyManua.ls Logo

ABB OmniCore V250XT Type B - Page 99

ABB OmniCore V250XT Type B
468 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The emergency stop input needs to be connected to an emergency stop device.
This to allow operation in both automatic and manual mode:
6
5
7
2
4
3
1
8
0
V_IO_EXT
24V_CH1_EXT
EXT_ESTOP_CH1_P
EXT_ESTOP_CH1_N
0V_IO_EXT
24V_CH2_EXT
EXT_ESTOP_CH2_P
EXT_ESTOP_CH2_N
A2.K5.X14
Customer provided
emergency stop device
xx2300000997
The emergency stop input can be powered from an external power supply:
6
8
5
7
2
1
4
3
C
ustomer_24V_CH1
Customer_24V_CH2
Customer_0V_CH1
Customer_0V_CH2
Customer provided power
0V_IO_EXT
24V_CH1_EXT
EXT_ESTOP_CH1_P
EXT_ESTOP_CH1_N
0V_IO_EXT
24V_CH2_EXT
EXT_ESTOP_CH2_P
EXT_ESTOP_CH2_N
Customer provided
emergency stop device
A2.K5.X14
xx2300000998
Continues on next page
Product manual - OmniCore V250XT Type B 99
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
3 Installation and commissioning
3.5.9 Descriptions for connectors
Continued

Table of Contents

Related product manuals