A
500
Operator
interface: control
panel
GB
00209
-
Edition 02
-
September
04
F1
18
17
F3
16
F2
LEAK RATE
COR
14
15
mbar.l /
s
Pa.m
3
/s
Torr.l/
s
Operation
par
t
mbar.l/
s
F4
10
-12
10
-11
10
-10
10
-9
10
-8
10
-7
10
-6
10
-5
10
-4
10
-3
10
-2
12
11
13
F1
F2
LEAK RATE
F3
COR
Pa.m
3
/s
Torr. l/s
10
-3
10
-2
10
-1
1
10
1
10
2
10
3
mba
r
8
9
10
F4
10
-12
10
-11
10
-10
10
-9
10
-8
10
-7
10
-6
10
-5
10
-4
10
-3
10
-2
20 21 22
23
19
NEXT
-
+
RESET
SET POINTS
SPECTRO
MAINTENANCE
OTHER
1
INL ET
PRESSU RE
AUTO CAL
2
SNIFFER
hP
a
Torr
ZERO
STDBY
EVAC
TEST
NEXT
-
+
RESE T
10
-3
10
-2
10
-1
1
10
1
10
2
10
3
INLET
PRESSURE
mba
r
hP
a
Torr
STDBY
EVAC
TEST
24
25 26 27
28
29
3 4
5
CYCLE
6
SET POINTS
SPECTRO
MAINTENANCE
OTHER
AUTO CAL
SNIFFER
ZERO
CYCLE
7
1 Inlet port pressure
analog display
2 Control and menu selection indicators (ON when
activated)
3 Auto-calibration
STAR
T/ABOR
T
control key
4 Sniffing mode
ON/OFF
control key
5 Auto-zero
ON/OFF
control key
6 Cycle
START/STOP
control key
7 Control keys (4 keys)
8 Standby
ON/OFF indicator
9 Evacuation
ON/OFF indicator
10
T
est
ON/OFF
indicator
t
Setting and
maintenance
part
(*)
*
Operator
access to setting and
maintenance
part
depends
on the user interface level.
User interface level C
120
11 Helium signal
analogic display
12 Helium signal
analogic
scale
ON/OFF indicator
13 Helium signal Zero scale
ON/OFF indicator
14 Correction factor COR indicator (applied to digital
display)
15 Units
ON/OFF indicator
Parameter
function keys (1 key per display line)
F1
F2
F3
LEAK RATE
COR
Helium signal
display
mbar.l/
s
Pa.m
3
/s
Torr. l/s
16 Helium signal digital
display
17 Alphanumeric display (4 lines x 20
characters)
F4
10
-12
10
-11
10
-10
10
-9
10
-8
10
-7
10
-6
10
-5
10
-4
10
-3
10
-2
10
-3
10
-2
10
-1
1
10
1
10
2
10
3
mba
r
18
Parameter function keys (1 key per display line)
19 Modification access keys (4 keys)
20
NEXT
: next
display/parameter
circular function
21/22
Plus or minus value adjustment,
parameter
selection, audio volume adjustment keys
23
RESET
of previously
displayed
values (cancels temporary inputs)
24 Menu selection access keys (4 keys)
NEXT
-
+
RESET
SET POINTS
SPECTRO
MAINTENANCE
OTHER
INLET PRESS URE
AUTO CAL
SNIFFER
hP
a
Torr
ZERO
STDBY
EVAC
TEST
CYCLE
25
SET
POINT menu selection key
Modification access keys (4 keys) Control keys (4 keys)
and
26
SPECTRO
calibration
and
analyzer
cell configuration menu selection key
27 MAINTENANCE menu selection key
28
OTHER
menus selection key (test mode selection, inlet
VENT
selection,
date/time)
29 Remote control
connection
Menu selection
access
keys (4 keys)
control and menu selection
indicators
(ON when
activated)
Remote control interface C
400
Control panel with graphic interface (option) C
440
2
/2