89
Rammax 1515-M/-MC/-MI/-MCI
Index: a; Issued 08/2010
Remove the clamp on the suction lter.
Remove the suction lter with a No. 70 wrench.
Clean or replace the suction lter element.
Install the suction lter element with Omnit 100M.
Install the components again in reverse order.
The return lter is located on the underside of the control unit
(Fig. MW11).
Fig. MW11: Return lter
Remove the lter housing with a No. 36 box wrench.
Screw off the lter housing and replace the lter cartridge.
Replace the O-ring and screw the lter housing back on.
Turn the lter housing tight with the box wrench and then
turn it 1/8 of a rotation back again.
NOTE
If the lter housing is on too tight, thermal effects during operati-
on will cause it to stick. Then it cannot be removed again.
Never tighten the housing all the way!
Pour in the hydraulic oil until its level reaches the middle
of the oil viewing window.
Inspect the hydraulic system for leaks. ► Start the diesel
engine and leave it to run at idle for 5 minutes. ► Check
the oil level at the oil level gauge once again. Rell with
hydraulic oil as necessary. Recommended types of oil
see technical data.
Maintaining the Machine