Chapter 3 Measurement
3-62
Level Offset
Summary
Sets the level adjustment coefficient of the Noise signal output.
This setting is enabled when Waveform is set to Noise.
Setting range
–20.0 to 20.0 dB
Offset
Summary
Enables/disables the offset function of the Noise signal output.
The setting is available when Waveform is set to Noise.
Options
On Enables the offset function of Noise signal
output.
Off Disables the offset function of Noise signal
output.
G.227 Filter
Summary
Enables/disables the pseudo voice filter (G.227).
This setting is enabled when Waveform is set to Noise.
Options
On Enables the pseudo voice filter (G.227).
Off Disables the pseudo voice filter (G.227).
Code
Summary
Sets the DTMF signal code.
This setting is enabled when Waveform is set to DTMF.
Setting range
0 to 9, A to D, *, #
(Selects one from the above.)
Level
Summary
Sets the DTMF signal output level.
This setting is enabled when Waveform is set to DTMF.
Setting range
When Output Type is Bal.:
0.001 to 3.000 Vp
When Output Type is Unbal.:
0.001 to 1.500 Vp