Operating Guide 52
Antelope Camera Systems
Iris Speed
This parameter defines the speed of the iris motor in percent. The recommended default values are
40% for the encoder setting and 100% for the DC setting.
Values range from 0 - 100%
Iris Ct. Loc. - Here you can select whether to control the iris motor via OCP or via external hand
rocker (connected to CCU).
Values are
CCU
OCP
Note! If no motor is attached the Iris Ct. Loc. is - NO -
Focus Speed
This parameter defines the speed of the focus motor in percent. The recommended default values
are 40% for the encoder setting and 100% for the DC setting.
Values range from 0 - 100%
Focus Ct. Loc. - Here you can select whether to control the focus motor via OCP or via external
hand rocker (connected to CCU).
Values are
CCU
OCP
Note! If no motor is attached the Focus Ct. Loc. is - NO -
Zoom Speed
This parameter defines the speed of the zoom motor in percent. The recommended default values
are 40% for the encoder setting and 100% for the DC setting.
Values range from 0 - 100%
Zoom Ct. Loc. - Here you can select whether to control the zoom motor via OCP or via external
hand rocker (connected to CCU).
Values are
CCU
OCP
Note! If no motor is attached the Zoom Ct. Loc. is - NO -
DC Zoom Rel
Here you select how the connected external hand rocker operates.
Values are
Absolute