CHAPTER
FIVE
CALIBRATION
Calibration is the process of checking and adjusting a scanner’s measurements by
comparing them with the standard (etalon) values. All Artec Leo scanners are
delivered pre-calibrated and issued with a calibration certicate (2022 onwards).
However, In some cases, owing to careless handling or transportation (jolts, acci-
dental drops or some other reason), Leo may fail to produce best results. In order
to resolve these issues, you can recalibrate your Leo.
5.1 Leo Recalibration
To recalibrate your Leo, you need a Calibration Board.
Step 1: Calibration board setup
1. Open the case containing the Leo Calibration board and place it on a at
surface, preferably the oor.
2. Detach the lid from the case, but donot take the Calibration board out of the
casing.
3. Avoid touching the board as it can damage the markings and tamper with
the calibration results.
Important: It is advised to handle the Calibration board with utmost care.
Perform calibration while keeping the board inside its casing always.
Step 2: Preparation
1. Turn on Leo, and if calibrating for the rst time, make sure it is connected
to Wi.
67