iHP Manual 111 | P a g e
iHP Owners Manual
Command
Command Name
Remarks
ISOCOMM will read each module output current reporting.
ISOCOMM will average the reported output current of the
modules in the group.
0x8Dh
READ_TEMPERATURE_1
ISOCOMM will read each module temperature reporting.
ISOCOMM will report the highest temperature reading of the
modules in the group.
0x96h
READ_POUT
ISOCOMM will read each module output power reporting.
ISOCOMM will sum up each module reported output power in a
group.
0x9Ah
MANUFACTURING
MODEL
ISOCOMM will report the modules Manufacturing Model.