AS64 series AC servo drive Function codes
-128-
6.4 I/O management (group P3)
6.4.1 Digital input/output
P3.00
1
Input of digital 1
Setting range
Default
Unit
Applicable
mode
0x000–0x136
0x003
-
P
S
T
This parameter specifies the input of digital 1. It is in the hexadecimal format.
In the expression of 0x*——, * indicates the valid mode, the value 0 indicates the input is valid
when the optical coupler is conductive, while the value 1 indicates the input is valid when the
optical coupler is not conductive.
In the expression of 0x—**, ** indicate the function settings. The detailed function settings are
listed in the following.

Table of Contents