AS64 series AC servo drive Appendix
-283-
10.1 Parameters about settings
Note:
In the Applicable mode column, P indicates position mode, S indicates speed mode, and T indicates
torque mode.
For function codes:
Marked with the superscript "1", the parameter settings take effect only after the drive is restarted
or repowered on.
Marked with the superscript "2", the parameter settings take effect only when the servo stops. The
modification during running does not take effect.
Marked with the superscript "*", the parameter settings are not stored after the drive is powered
off.
Function
code
Parameter
Unit
Setting range
Default
Applicable
mode
P0 Basic control
P0.00
1
Motor model
-
09999999
1010104
PST
P0.01
1
Encoder type
-
112
4
PST
P0.02
1
Forward direction of motor
rotating
-
01
0
PST
P0.03
1
Control mode
-
09
0
PST
P0.04*
Internal enabling
command
-
01
0
PST
P0.05
Jogging speed
r/min
01000
200
PST
P0.06
1
Numerator of frequency
division output coefficient
-
0–(2
31
-1)
10000
PST
P0.07
1
Denominator for
frequency division output
coefficient
-
1–(2
31
-1)
131072
PST
P0.08
1
Reverse frequency
division output
-
01
0
PST
P0.09
Torque limit mode
-
06
1
PS
P0.10
Max. torque limit 1
%
0.0500.0
300.0
PST
P0.11
Max. torque limit 2
%
0.0500.0
300.0
PS
P0.12
Input type of 3PH servo
power
-
01
0
PST
P0.13
1
External brake resistor
power
W
05000
200
PST

Table of Contents