EasyManua.ls Logo

Astraada SRV-64 - Extension and Application

Astraada SRV-64
325 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AS64 series AC servo drive Function codes
-153-
0–1
0
-
P
S
T
This parameter specifies whether to enable external fault reporting for the drive.
Setting
Meaning
[0]
Disable
1
Enable
P4.22*
Data size
16bit
Data format
DEC
Modbus address
1844, 1845
CANopen address
0x2416, 0x00
P4.23*
Emergency stop
command
Setting
range
Default
Unit
Applicable
mode
0–1
0
-
P
S
T
This parameter specifies whether to enable emergency stop for the drive.
Setting
Meaning
[0]
Disable
1
Enable
P4.23*
Data size
16bit
Data format
DEC
Modbus address
1846, 1847
CANopen address
0x2417, 0x00
P4.24*
Vibration control
switching command
Setting
range
Default
Unit
Applicable
mode
0–1
0
-
P
This parameter specifies whether to enable vibration control switching for the drive.
Setting
Meaning
[0]
Disable
1
Enable
P4.24*
Data size
16bit
Data format
DEC
Modbus address
1848, 1849
CANopen address
0x2418, 0x00
6.5.3 Extension and application
P4.30
Stop mode
Setting
range
Default
Unit
Applicable
mode
0–3
0
-
P
S
T
This parameter specifies whether the dynamic brake works when the servo is off and a fault alarm is
reported and determine the servo motor status after the stop.
Setting
Action
During deceleration
After stop
[0]
The motor coasts to stop.
Inertia running kept
1
The motor stops through the
dynamic brake.
Inertia running kept

Table of Contents