EasyManua.ls Logo

Astraada SRV-64 - Page 290

Astraada SRV-64
325 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AS64 series AC servo drive Appendix
-284-
Function
code
Parameter
Unit
Setting range
Default
Applicable
mode
P0.14
1
External brake resistor
resistance
Ω
11000
60
PST
P0.15
Default monitored
parameters
-
022
0
PST
P0.16
Parameter modification
lock
-
01
0
PST
P0.17
Mode for writing to
EEPROM
-
01
0
PST
P0.18*
Factory password
-
065535
0
PST
P0.19
Main circuit power input
type
-
01
0
PST
P0.20
1
Position command source
-
04
0
P
P0.22
1
Pulses per motor
resolution
reference unit
0–(2
31
-1)
10000
P
P0.23
1
Pulse input mode
-
02
0
P
P0.24
1
Reverse pulse input
direction
-
01
0
P
P0.25
Numerator of electronic
gear ratio 1
-
0–(2
31
-1)
0
P
P0.26
2
Denominator of electronic
gear ratio
-
1–(2
31
-1)
10000
P
P0.27
Numerator of electronic
gear ratio 2
-
0–(2
31
-1)
0
P
P0.28
Numerator of electronic
gear ratio 3
-
0–(2
31
-1)
0
P
P0.29
Numerator of electronic
gear ratio 4
-
0–(2
31
-1)
0
P
P0.33
2
Position command
smooth filter time
ms
0.01000.0
0.0
P
P0.34
2
Position command FIR
filter time
ms
0.01000.0
0.0
P
P0.35
Software limit in CCW
position control
reference unit
-(2
31
-1)(2
31
-1)
0
P
P0.36
Software limit in CW
position control
reference unit
-(2
31
-1)(2
31
-1)
0
P
P0.37
Position command mode
-
01
0
P

Table of Contents