AS64 series AC servo drive Function codes
-156-
Main-power UV
detection time
This parameter specifies the time taken to detect main power undervoltage.
Note: The value 0 indicates the function of detecting main power undervoltage is invalid.
The parameter specifies the overload rate of the motor.
The default value is 115.0%. When the value of the parameter is enlarged, please take the motor
overload capacity into consideration.
Speed deviation
threshold
This parameter specifies the condition for detecting the speed deviation fault. If the absolute value
of the actual speed command minus the motor speed is greater than the setting of this parameter
and the deviation lasts more than 100ms, a speed deviation alarm is reported.
Note: The value 0 indicates no detection on speed deviation faults.
This parameter specifies the maximum limit on the forward speed command.
Note: The default value and setting range of this parameter are associated with the drive power
class.