AW00089317000 Image Acquisition Control
Basler ace GigE 149
acA1300-60gm/gc
acA1300-60gmNIR
43 µs 190 to 200 µs (*) 35 to 48 µs (*)
acA1600-20gm/gc 45.54 µs - -
acA1600-60gm/gc 41.5 µs 180 to 240 µs (**) 34 to 51 µs (**)
acA2000-50gm/gc
acA2000-50gm/gc - CMV2000-V3
0.2 to 17.2 µs (with
frame acquisitions
overlapped)
0.2 µs (with frame
acquisitions not
overlapped)
--
acA2000-50gmNIR
acA2000-50gmNIR - CMV2000-V3
acA2040-25gm/gc
acA2040-25gm/gc - CMV4000-V3
acA2040-25gmNIR
acA2040-25gmNIR - CMV4000-V3
acA1920-25gm/gc
acA2500-14gm/gc
- 848 to 883 µs (***) 848 µs
*** Depends on the exposure time
*** Depends on the exposure time and the pixel format.
*** Depends on whether the frame acquisitions are overlapped or not overlapped.
Exposure Start Delay
Camera Model Global Shutter
Rolling Shutter
ERS Mode
(Default)
GRR Mode
Table 20: Exposure Start Delays