EasyManuals Logo

Basler GigE SERIES User Manual

Basler GigE SERIES
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #159 background imageLoading...
Page #159 background image
AW00089317000 Image Acquisition Control
Basler ace GigE 149
acA1300-60gm/gc
acA1300-60gmNIR
43 µs 190 to 200 µs (*) 35 to 48 µs (*)
acA1600-20gm/gc 45.54 µs - -
acA1600-60gm/gc 41.5 µs 180 to 240 µs (**) 34 to 51 µs (**)
acA2000-50gm/gc
acA2000-50gm/gc - CMV2000-V3
0.2 to 17.2 µs (with
frame acquisitions
overlapped)
0.2 µs (with frame
acquisitions not
overlapped)
--
acA2000-50gmNIR
acA2000-50gmNIR - CMV2000-V3
acA2040-25gm/gc
acA2040-25gm/gc - CMV4000-V3
acA2040-25gmNIR
acA2040-25gmNIR - CMV4000-V3
acA1920-25gm/gc
acA2500-14gm/gc
- 848 to 883 µs (***) 848 µs
*** Depends on the exposure time
*** Depends on the exposure time and the pixel format.
*** Depends on whether the frame acquisitions are overlapped or not overlapped.
Exposure Start Delay
Camera Model Global Shutter
Rolling Shutter
ERS Mode
(Default)
GRR Mode
Table 20: Exposure Start Delays

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler GigE SERIES and is the answer not in the manual?

Basler GigE SERIES Specifications

General IconGeneral
InterfaceGigE
Lens MountC-Mount, CS-Mount
SensorCMOS
MountC-mount, CS-mount
Power SupplyPower over Ethernet (PoE)
DimensionsVaries by model
WeightVaries by model
Operating TemperatureVaries by model

Related product manuals