Image Acquisition Control AW00089317000
150 Basler ace GigE
FTWait
Signal
ExFSTrig
Signal
Exposure
Frame
Readout
Frame
Transmission
Exposure
Frame N
Frame N+1 Readout to the Frame Buffer
Frame N+1 Transmission to Host PC
Frame N Readout to the Frame Buffer
Frame N Transmission to Host PC
Exposure
Frame N+1
Exposure
Frame N+2
Transmission Start DelayTransmission Start Delay
Timing charts are not drawn to scale
Exposure Start Delay Exposure Start Delay
Fig. 81: Exposure Start Controlled with an ExFSTrig Signal