Page #160 background imageLoading...
Page #160 background image
Image Acquisition Control AW00089317000
150 Basler ace GigE
FTWait
Signal
ExFSTrig
Signal
Exposure
Frame
Readout
Frame
Transmission
Exposure
Frame N
Frame N+1 Readout to the Frame Buffer
Frame N+1 Transmission to Host PC
Frame N Readout to the Frame Buffer
Frame N Transmission to Host PC
Exposure
Frame N+1
Exposure
Frame N+2
Transmission Start DelayTransmission Start Delay
Timing charts are not drawn to scale
Exposure Start Delay Exposure Start Delay
Fig. 81: Exposure Start Controlled with an ExFSTrig Signal

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler GigE SERIES and is the answer not in the manual?

Basler GigE SERIES Specifications

General IconGeneral
InterfaceGigE
Lens MountC-Mount, CS-Mount
SensorCMOS
MountC-mount, CS-mount
Power SupplyPower over Ethernet (PoE)
DimensionsVaries by model
WeightVaries by model
Operating TemperatureVaries by model