Calculated scalar values Part C VC-6000
TM
Compact monitor
© VC-6000
TM
Compact monitor Sept.2011 C100583.002 Components Vers. 07 - 61 -
19.2 Max (X,Y) peak-peak
Measurement method B for monitoring shaft vibration
according to DIN ISO 7919: An X/Y displacement sensor pair
with relative orthogonal measurement directions produces
two measured peak-peak values, of which only the greater of
both current values is used for further assessment.
19.3 Peak calculated
The peak-calculated value corresponds to the RMS-value
multiplied by the factor
2
.
19.4 Peak-Peak calculated
The peak-peak-calculated value from the product of the
RMS-value and the factor 2x
2
.
19.5 Crest Factor
The Crest Factor is formed from the measured peak-value
divided by the measured RMS-value.