VC-6000
TM
Compact monitor Part C DC output
- 74 - C100583.002 Components Vers. 07 © VC-6000
TM
Compact monitor Sept. 2011
23 DC output
23.1 Function
The DC output is an optional signal path component. As a configuration
interface it contains a group of parameters that are necessary for setting
of a respective DC output channel. If more DC outputs are available,
each individual output is set up by its individual DC output block.
Each DC output is used for setting all the important output parameters.
In particular the linearity of the DC output signal is set here.
23.2 Parameters and their setting ranges
23.2.1 Parameter list
<Socket no.>
This parameter informs you about the physical socket number of the
corresponding DC output, or the associated output module.
The settings are determined by the application firmware of the
VIBROCONTROL 6000 Compact monitor and cannot be changed at the
instrument.
Note:
The function of a DC output is guaranteed only if the physical module
configuration is not changed!
Possible socket numbers 1, 2, 3, 4, 5, 6, 7, 8 or 9
<Channel no.>
This parameter informs you about the physical channel layout of the DC
output on the associated output module. The settings are determined by
the application firmware of the VIBROCONTROL 6000 Compact monitor
and cannot be changed at the instrument.
Possible channel numbers A or B