Cycle-DC measurement Part C VC-6000
TM
Compact monitor
© VC-6000
TM
Compact monitor Sept.2011 C100583.002 Components Vers. 07 - 59 -
<Multiplier>
The Multiplier is length L2 (distance between crosshead and piston ring)
Minimum: 1 Maximum: 99999 Step size: 1
Works pre-setting 1
<Divider>
The Divider is length L1 (distance between crosshead andthe con-rod
centre position).
.
Minimum: 1 Maximum: 99999 Step size: 1
Works pre-setting 1
The geometry factor is formed from the parameters „Multiplier“ and
„Divider“. In the rod-drop monitoring application the geometry factor is
used to geometrically compensate for the movement between the
measurement position and the position of the piston ring.
If the geometry factor = Multiplier / Divider is set to 1, the Cycle-DC
measurement can be used for general purpose applications.
18.2.2 Summary of the parameters
Parameter name Value range changeable
Mode One position, two positions or
averaged cycle
Yes
No. of averages 1...99999 Yes
Zero offset -9999.99...+ 9999.99 Yes
Meas. position 1 0...+ 360° Yes
Meas. position 2 0...+ 360° Yes
Time out 0.1 s...100.00 s Yes
Multiplier 1...99999 Yes
Divider 1...99999 Yes