9-1
Bosch Security Systems 10/22 BLCC615I
SECTION 9
Comms Programming
T
here are two independent reporting routes that
define where a reportable event should be sent, by
default all events will report through route 1. Reportable
events in the system are categorised into Alarm, System,
Emergency, Open/Close and Test. This means that you are
able to steer these different event categories to different
report routes. A report route is just like an independent
communicator.
Example: Route 1 = MyAlarm, Route 2 = Ethernet/WiFi
If you set the reporting route for Open/Close as Route 2
and all other events to Route 1, then all reports will be
sent to route 1 via MyAlarm and then forwarded to the
monetoring company and then all open close reports will
be sent direct to the base station via IP using an optional
keypad with built-in WiFi or via the optional ethernet
module.
COMMS PROGRAMMING COMMANDS
Comms > Commands >
Start Direct Link
-
MENU 5-0-5
This menu allows the installer or master user to start a
direct link session without the need to press and hold the
default button on the control panel.
1) Enter [MENU] + [5] + [0] + [5]. The keypad will
display the following:
Waiting for Direct Link
Attempt!
Press OK or MENU
Once the computer and control panel establishes a
connection, the command will automatically exit.
2) Press [OK] or [MENU] to exit.
Comms > Commands >
Register Customer
-
MENU 5-0-8
This menu is used to enter the customer registration
number into the control panel. This unique 11 digit
number is generated by the system owner when they
create an account on MyAlarm web site.
This is required for panels using the MyAlarm iFob
Control App. See the MyAlarm website for more
information at www.myalarm.com.au
Comms > Commands >
Register Installer
MENU 5-0-9
This menu is used to enter the installer registration
number into the control panel. This unique 11 digit
number is generated by the installer when they create an
installer account on the MyAlarm web site.
This number should be entered into all panels installed
by the installer allowing them to view all of their panels
via the MyAlarm web site.

Table of Contents

Other manuals for Bosch Solution 6000-IP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 6000-IP and is the answer not in the manual?

Bosch Solution 6000-IP Specifications

General IconGeneral
Event LogYes
Areas1
Partitions1
Outputs2
CommunicationIP, GSM
Mobile AppYes
AutomationYes
System TypeHybrid
Battery BackupYes
KeypadsUp to 8