Solution 6000-IP
Installation Manual Comms Programming
9-10
Bosch Security Systems 10/22 BLCC615I
Username Rr1
Press  OK to SAVE
4) Use the [0] to [9] and [] and [] keys to program
the parameter, then press [OK] to save and exit or
press [MENU] to exit without saving.
Comms > IP Reporting >
Reporting Options
MENU 5-6-1-0
1 Use SIA Format N
2 SIA With Text N
3 32 Bit Checksum N
4 Reserved N
5 Reserved N
6 Reserved N
7 Reserved N
8 Reserved N
This menu allows the installer to select which IP options
are allowed.
1) Press [MENU] + [5] + 6] + [1] + [0].
The keypad will display the current options which are
selected or enabled.
Use SIA Format
SIA With Text
32 Bit Checksum
Press  OK ON OFF MENU
2) Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
3) Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Use SIA Format
SIA IP allows alarm reports to be sent over IP. The
standard provides the sender the ability to format the
report in a Contact ID format or SIA format. Prior to
version 2.30, implementation of SIA IP formatted the
event in Contact ID only.
SIA With Text
When the control panel is configured to report using SIA
IP, this option will allow applicable events to include text
with the report.
32 Bit Checksum
This allows the control panel to report SIA IP using a 32
Bit checksum. Otherwise the control panel will report SIA
IP using a 16 Bit checksum.
Comms > IP Remote Access >
IP Address
-
MENU 5-7-0
Installer
1 Digits 12
0 0 0 0 0 0 0 0 0 0 0 0
User
1 Digits 12
0 0 0 0 0 0 0 0 0 0 0 0
The Installer IP address can be specified which will restrict
IP Solutionlink sessions to a PC that is at the specified
address. This feature is similar to call back verification as
an IP upload/download session can only be establish from
one specific location (IP Address). If you want to be able
to access the control panel from multiple locations using
Solutionlink over an IP connection then please leave this
location blank.
1) Press [MENU] + [5] + [7] + [0]. The keypad will
prompt you to enter which Solution Link IP address
(IP 1 = Installer or IP 2 = User) that you want to
program.
Installer
User
Exit
Press  OK or MENU
The installer can now select either the installer
Solution Link IP address or the user Solution Link IP
address by using the up and down arrow keys. If the
Master user programs this menu, the keyapd will only
display the option to program the user IP address:
2) Select the which IP address that you want to
change (installer or user), then press [OK] to enter.
3) The keypad will display the first six digits of the
Solution Link IP address.
RAS IP Address
000000000000
Press  OK to SAVE
4) Use the numeric keys [0] to [9] + [] and [] keys
to program the IP Address, then press [OK] to save
and exit or press [MENU] to exit without saving.