Solution 6000-IP
Installation Manual Programming Examples
12-3
Bosch Security Systems 10/22 BLCC615I
Door Auto Lock/Unlock By TimeZone
The control panel is capable of automatically unlocking
and locking single door or multiple doors using a single
timezone.
Programming the TimeZone Auto Unlock/Lock Times
1) Select a timezone that is not used and program the
timezone name (description) in MENU 7-5-0.
2) Set the timezone start time (Door Auto Unlock
Time) and stop time (Door Auto Lock Time) in
MENU 7-5-1.
3) Set the days of the week that the timezone will
operate (including holidays if required) in MENU
7-5-2.
Programming Output For Door Operation
4) Select an output that is not used and program the
output name in MENU 4-1-0.
5) In MENU 4-1-1, set the output event type as 60 -
Door.
6) In MENU 4-1-2, set the output event assignment to
the door number that you wish to control (eg. 01 -
Door 1 Name).
7) In MENU 4-1-3, set the output polarity for the door
operation (eg. 04 - Open, One Shot Low).
8) In MENU 4-1-4, set the time that you want the door
to unlock when a user presents their credentials
(eg. 000 000 005 000 = 5 seconds).
Setting the Door Options
9) Select the door that will follow the timezone and
program the door name (description) in MENU 4-2-
0.
10) Set the timezone that the door that will follow for
auto lock/unlock in MENU 4-2-2. Multiple doors
can be programmed to follow the same timezone if
required.
11) Set the door options as required in MENU 4-2-3
(default = Hold Off Unlock If Area Armed).
Setting Console Door Assignment
12) Program the console (keypad/reader) door
assignment in MENU 6-1-7.
13) Program other console (keypad/reader) options as
required including Home Area, Area Options and
General Options.
Setting User Door Assignment
14) In MENU 1-4-5. assign each user to the door being
used as required. Each user can be assigned to
multiple doors.
15) Program the users PIN, token, fingerprint as
required.
»»END OF SECTION««