Solution 6000-IP
Installation Manual Device Programming
10-7
Bosch Security Systems 10/22 BLCC615I
2) Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
3) Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Extinguish
This option allows the LAN device (eg. keypad, proximity
reader or fingerprint reader) to automatically turn off
all key backlighting and status LED's when there is no
activity for approximately 4 minutes. As soon as an
alarm occurs or user activity on the LAN device, the
backlighting and/or status LED's will return to normal.
Greetings
This option allows the keypad to breifly display on the
top line the greeting message when a user turns an area
on or off.
When turning an area All On, Part On or Part 2 On, the
greeting message 'Goodbye' along with their user name
on the second line will be displayed:
Goodbye
Mary Smith
Security System ON
When turning an area off from All On, Part On or Part 2
On, the greeting message will by displayed on the top
line along with their user name on the second line.
The following greeting messages are as follows:
Good Morning Greeting = 00:00 to 11:59
Good Afternoon Greeting = 12:00 to 17:59
Good Evening Greeting = 18:00 to 23:59
Good Morning
Mary Smith
Security System OFF
Display Temperature
This option allows the keypad to display the reading of
the keypad temperature when a keypad idle screen has
been programmed. Each keypad can display its own
temperature.
Display Area Icons
This option allows the keypad to display the area icons 1
to 8. This allows the users to determine which areas are
turned All On or Part On from a single keypad without
the need to either move the keypad display to view each
area or walk to each area keypad.
Thu,Jan,05 11:22 am 22ºC
Security System
DISARMED
Trouble Alert Beeps
This option allows the LAN device (keypad, proximity
reader or fingerprint reader) to sound a trouble tone
when the system has detected a trouble condition.
Entry Exit Warning
This option allows the LAN device (keypad, proximity
reader or fingerprint reader) to sound the entry warning
tone or sound the exit warning tone when a user turns
an area All On.
Part Exit Warning
This option allows the LAN device (keypad, proximity
reader or fingerprint reader) to sound the exit warning
tone when a user turns the area Part On or Part 2 On.
If this option is not programmed, the keypad will only
sound a single beep at the end of the part exit time.
Chime Tone
This option allows the LAN device (keypad, proximity
reader or fingerprint reader) to sound the chime tone
when a zone set to be monitored when chime mode is
turned on is faulted. If this option is not programmed,
the LAN device will not sound the chime tone when a
chime zone is faulted.
Devices > Keypads & Readers >
Emergency Keys
MENU 6-1-6
1 Audible Keypad Fire Y
2 Report Keypad Fire Y
3 Audible Keypad Medical Y
4 Report Keypad Medical Y
5 Audible Keypad Panic Y
6 Report Keypad Panic Y
7 Reserved N
8 Reserved N
The above options can be configured independantly for
each keypad fitted to the system.
1) Press [MENU] + [6] + [1] + [6] and use the up and
down arrows to highlight the keypad in the list
then press [OK].

Table of Contents

Other manuals for Bosch Solution 6000-IP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 6000-IP and is the answer not in the manual?

Bosch Solution 6000-IP Specifications

General IconGeneral
Event LogYes
Areas1
Partitions1
Outputs2
CommunicationIP, GSM
Mobile AppYes
AutomationYes
System TypeHybrid
Battery BackupYes
KeypadsUp to 8

Related product manuals