EasyManuals Logo

Bosch Solution 6000-IP Installation Guide

Bosch Solution 6000-IP
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #114 background imageLoading...
Page #114 background image
Solution 6000-IP
Installation Manual Comms Programming
9-14
Bosch Security Systems 10/22 BLCC615I
Comms > Comms Test >
Test Report Period
MENU 5-9-2
(*** System Wide Parameter ***)
0 1
00 - No Test Report 08 - Reserved
01 - Every Day 09 - Reserved
02 - Every Week 10 - Reserved
03 - Every Month 11 - Reserved
04 - Every 2 Days 12 - Reserved
05 - Every 3 Days 13 - Reserved
06 - Every 4 Days 14 - Every Hour
07 - Every 5 Days 15 - Every 12 Hours
This menu programs how often the control panel will
send a test report. Only one option can be programmed.
1) Press [MENU] + [5] + [9] + [2]. The keypad will
display the current Test Report Period.
Test Report Period
01 - Every Day
Press  0-9 OK to SAVE
2) Use the up and down arrow keys to select the Test
Report Period then press [OK] to save and exit or
press [MENU] to exit without saving.
Comms > Comms Test >
Test Report Options
MENU 5-9-3
1 Test If No Other Rpt N
2 Test On Siren Reset Y
3 Reserved N
4 Reserved N
5 Reserved N
6 Reserved N
7 Reserved N
8 Reserved N
1) Press [MENU] + [5] + [9] + [3]. The keypad will
display the current Test Report Options.
Test If No Other Rpt
Test On Siren Reset
Reserved
Press  OK ON OFF MENU
2) Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
3) Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Test If No Other Rpt
Setting this option will cause the system to only send its
automatic Test report if no other area report has been
sent within the test report time period as programmed in
MENU 5-9-2.
Test On Siren Reset
Setting this option will delay the Automatic Test Report if
the sirens are running when the test report time expires.
This effectively allows the control panel to send any
further alarm reports which may be triggered while the
sirens are running. The panel will send the cued Test
Report as soon as the siren run-time has expired.
Comms > Comms Test >
Test Route
MENU 5-9-4
00 - Log Events Only 0 1
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
This menu programs which destination will be used to
send both manual and automatic test reports.
(*** System Wide Parameter ***)
1) Press [MENU] + [5] + [9] + [4]. The keypad will
display the current Test Route.
Test Route
01 - Dest 1 + Log
Press  0-9 OK to SAVE
2) Use the up and down arrow keys to select the Test
Route required then press [OK] to save and exit or
press [MENU] to exit without saving.
»»END OF SECTION««

Table of Contents

Other manuals for Bosch Solution 6000-IP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 6000-IP and is the answer not in the manual?

Bosch Solution 6000-IP Specifications

General IconGeneral
Event LogYes
Areas1
Partitions1
Outputs2
CommunicationIP, GSM
Mobile AppYes
AutomationYes
System TypeHybrid
Battery BackupYes
KeypadsUp to 8