Solution 6000-IP
Installation Manual System Programming
11-15
Bosch Security Systems 10/22 BLCC615I
then do not set this option.
First Open Last Close
Setting this option will cause the system to only report
an opening signal to the base station when the first area
is disarmed and a closing signal when the last area has
been armed or turned All On.
Reset Siren All Users
Setting this option allows a user with a valid PIN to
silence alarm outputs from any keypad on the system
without the need to toggle the keypad to the area that
the alarm occurred.
If this option has not been programmed, the user will
need to toggle the keypad to the area the alarm occurred
in and then silence the alarm by entering their PIN
followed by the [OFF] key.
Power Up As Down
Setting this option will cause the panel to power up
in the same state as it was when it was powerd down.
For example with this option set if the panel is in the
disarmed state and all power is removed for service
work to be done. When the power is reapplied, the
panel will start in the disarmed state. Any zone that was
programmed as bypassed when the power was removed
will remain bypassed when the power supply has
restored.
If this option is not programmed, the system will always
power up in the armed All On state and any zones
bypassed prior to power loss will power up as un-
bypassed zones.
Fault ACK All Areas
Setting this option allow system trouble faults to be
acknowledged from any area or keypad on the system
without the need to toggle over to the area the fault
occurred in.
Delay Trouble Beeps
Setting this option will prevent any system trouble
events from sounding the keypad speaker between
the hours of 10pm until 7am. During this time, any new
trouble events will be shown in the keypad display.
If any trouble events are still in effect at 7am, the keypad
will begin sounding the trouble alert to notify the user
of the problem. The function is primarily for use in
residential installations.
Power Up Disarmed
Setting this option will allow the control panel to always
power up in the disarmed state after removing both the
battery and AC mains supply and then reapplying power.
Ignore Trouble On Arm
This option allows the control panel to ignore unsealed
zones and trouble conditions when a user arms an area.
Low battery conditions cannot be ignored and will
require the users input.
If this option is not set, when a user attempts to arm an
area with zones unsealed or existing trouble condition,
they will be required to press [OK] for each unsealed zone
or trouble condition before the area would arm.
System > System Options >
Keypad Idle Screen
MENU 7-7-2
(*** System Wide Parameter ***)
0 0
00 - No Idle Screen 02 - Time
01 - Date And Time 03 - Custom Screen
This menu allows you to select a keypad idle screen which
will appear on the display when there has been no activity
at the keypad for a period of 2 minutes. The keypad display
will return to normal as soon as any key has been pressed.
All keypads on the system will display the same screen
saver. See the examples below.
1) Press [MENU] + [7] + [7] + [2]. The keypad will
display the current Keypad Idle Screen option.
Keypad Idle Screen
00 - No Idle Screen
Press  0-9 OK to SAVE
2) Use the up and down arrow keys to select which
idle screen you want to display then press [OK] to
save and exit or press [MENU] to exit without
saving.
System > System Options >
Keypad Hi/Lo Temp
-
MENU 7-7-3
0 0 0
˚C
0 0 0
˚C
Hi TEMP Lo TEMP
(*** System Wide Parameter ***)
This menu allows you to set the keypad High and Low
temperature values which the system will monitor. Valid
temperatures are from 00 ˚C minimum to a maximum of
50 ˚C with a tolerance = +/- 1 ˚C.
If the temperature on the selected keypad falls below the
minimum set temperature then the keypad will display
‘Low Temp xx˚C If the temperature increases above the
maximum set temperature then the keypad will display
High temp xx˚C.
Where xx = the set temperature to be monitored.
(*** System Wide Parameter ***)
1) Press [MENU] + [7] + [7] + [3]. The keypad will
display the current temperature settings.

Table of Contents

Other manuals for Bosch Solution 6000-IP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 6000-IP and is the answer not in the manual?

Bosch Solution 6000-IP Specifications

General IconGeneral
Event LogYes
Areas1
Partitions1
Outputs2
CommunicationIP, GSM
Mobile AppYes
AutomationYes
System TypeHybrid
Battery BackupYes
KeypadsUp to 8

Related product manuals