Solution 6000-IP
Installation Manual Input Programming
7-16
Bosch Security Systems 10/22 BLCC615I
To test zone Zn1
open then close
Zone 1 Name
Press OK or MENU
3) Open and close the zone that needs to be tested.
When the test has been completed the keypad will
display:
Zn1 Zone 1 Name
Test Successful
Press OK or MENU
4) Press [OK] or [MENU] to exit.
Inputs > Input Testing >
Sensor Watch Time
MENU 3-9-2
(*** System Wide Parameter ***)
0 3 0
Days
This menu programs the Sensor Watch Time interval.
Zones programmed for Sensor Watch are required to seal
and unseal at least once within the Sensor Watch Time
period or a trouble message will be displayed on the
keypad and a Zone Trouble report sent.
Valid entries are 001 -255 Days and 000 = Sensor Watch
Disabled.
1) Press [MENU] + [3] + [9] + [2]. The keypad will
display the current sensor watch time (Default = 30
days).
Sensor Watch Time
030 Days
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the new Sensor
Watch time in days then press [OK] to save and exit
or press [MENU] to exit without saving.
i
Note
Sensor Watch monitoring is only active when the
area is in the disarmed state. 24 hour zone types
cannot be monitored using the Sensor Watch feature.
»»
END OF SECTION
««

Table of Contents

Other manuals for Bosch Solution 6000-IP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 6000-IP and is the answer not in the manual?

Bosch Solution 6000-IP Specifications

General IconGeneral
Event LogYes
Areas1
Partitions1
Outputs2
CommunicationIP, GSM
Mobile AppYes
AutomationYes
System TypeHybrid
Battery BackupYes
KeypadsUp to 8

Related product manuals