Solution 6000-IP
Installation Manual Device Programming
10-8
Bosch Security Systems 10/22 BLCC615I
Audible Keypad Fire
Report Keypad Fire
Audible Keypad Medical
Press  OK ON OFF MENU
2) Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
3) Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Audible Keypad Fire
Setting this option allows the panel to sound an audible
alarm when a Keypad Fire Emergency Alarm has been
triggered via the keypad. To initiate a fire emergency via
the keypad, press and hold the [4] + [6] keys or the [] +
[] keys down for two seconds. Enter a valid user PIN to
reset the alarm condition.
Report Keypad Fire
Setting this option allows the panel to send a Fire report
to the base station when a Keypad Fire Emergency Alarm
has been triggered via the keypad.
Audible Kpad Medical
Setting this option allows the panel to sound an audible
alarm when a Keypad Medical Emergency Alarm has
been triggered via the keypad. To initiate a medical
emergency via the keypad, press and hold the [7] + [9]
keys or the [] + [] keys down for two seconds. Enter a
valid user PIN to reset the alarm condition.
Report Kpad Medical
Setting this option allows the panel to send a Medical
report to the base station when a Keypad Medical
Emergency Alarm has been triggered via the keypad.
Audible Kpad Panic
Setting this option allows the panel to sound an audible
alarm when a Keypad Panic Emergency Alarm has been
triggered via the keypad. To initiate a panic emergency
via the keypad, press and hold the [1] + [3] keys or the
[] + [] keys down for two seconds. Enter a valid user
PIN to reset the alarm condition.
i
Note
If this option is disabled, a keypad panic alarm will
not be visible on the keypad display (i.e. Invisible
Panic Alarm).
Report Keypad Panic
Setting this option allows the panel to send a Panic
report to the base station when a Keypad Panic
Emergency Alarm has been triggered via the keypad.
Figure 26: Keypad Emergency Keys
Labelling can be applied to the keypad to further simplify
operation.
KEYPAD EMERGENCY ALARM TRIGGER’S
Key Sequence Event Triggered
[] + [] Hold for 2 seconds Keypad Fire Alarm
[] + [] Hold for 2 seconds Keypad Panic Alarm
[] + [] Hold for 2 seconds Keypad Medical Alarm
Table 31: Keypad Emergency Keys
Devices > Keypads & Readers >
Door Assignment
MENU 6-1-7
0 0
00 - No Door Assignment
01 - Door 1 Name 09 - Door 9 Name
02 - Door 2 Name 10 - Door 10 Name
03 - Door 3 Name 11 - Door 11 Name
04 - Door 4 Name 12 - Door 12 Name
05 - Door 5 Name 13 - Door 13 Name
06 - Door 6 Name 14 - Door 14 Name
07 - Door 7 Name 15 - Door 15 Name
08 - Door 8 Name 16 - Door 16 Name
This menu allows the installer to assign each keypad to a
single door group. 16 different door groups are available.
Programming a door group of zero (disabled) allows a
user with any door assignment to operate the keypad.
1) Press [MENU] + [6] + [1] + [7] and use the up and
down arrows to highlight the keypad or LAN reader
in the list then press [OK]. Alternatively, you can
enter the keypad or LAN reader number directly
and press [OK]. The keypad will display the current
door assignment setting.
Door Assignment Kp1
00 - No Door Assignment
Press  0-9 OK to SAVE
2) Use the up and down arrows to select the door
assignment that you want to assign the keypad or
LAN reader to.
3) Press [OK] to save and exit or press [MENU] to exit
without saving.

Table of Contents

Other manuals for Bosch Solution 6000-IP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 6000-IP and is the answer not in the manual?

Bosch Solution 6000-IP Specifications

General IconGeneral
Event LogYes
Areas1
Partitions1
Outputs2
CommunicationIP, GSM
Mobile AppYes
AutomationYes
System TypeHybrid
Battery BackupYes
KeypadsUp to 8

Related product manuals