EasyManuals Logo

Bosch Solution 6000-IP Installation Guide

Bosch Solution 6000-IP
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #120 background imageLoading...
Page #120 background image
Solution 6000-IP
Installation Manual Device Programming
10-6
Bosch Security Systems 10/22 BLCC615I
Security System
ALARM
Alarm Zone 1 Name
If the option is not programmed, the keypad will display
as below:
Security System
ALARM
Sat 06-Jan-2015 7:03pm
Reader Area Control
This option allows the user to control the alarm area as
well as access at the same time. Turning this option off
would make the console a pure access only device.
Reader Badging
This option allows the user to unlock a door (via Doors)
and also turn on or off an area from the same LAN reader
independently.
No Badging Badging Required
Area Is All On
Swipe Token Once
Open Door +
Disarm Area
Open Door +
Disarm Area
Area Is Off
Swipe Token Once
Open Door +
Turn Area All On
Open Door
Swipe Token 3
Times Within 5
Seconds
Open Door +
Turn Area All On
Swipe Token 4
Times Within 5
Seconds
Open Door +
Turn Area All On,
Switches To Part On
Table 28: Badging Examples
Non Badging
Area Is All On
Present Finger Once =
Open Door +
Turns Off All User Areas
Area Is Part On
Present Finger Once =
Open Door +
Turns Off All User Areas
Area Is Off
Present Finger Once =
Open Door +
Turns On All User Areas
Present Finger and Hold =
Opens Door +
Turns Part On All User
Areas
Table 29: Fingerprint - Non Badging Examples
Badging Allowed
Area Is All On
Present Finger Once =
Open Door +
Turns Off All User Areas
Area Is Part On
Present Finger Once =
Open Door +
Turns Off All User Areas
Area Is Off
Present Finger Once = Open Door
Present Finger and Hold =
Opens Door +
Turns On All User Areas
Table 30: Fingerprint - Non Badging Examples
Enable Egress Input
This option when selected will enable the egress input
on the rear of the control console. Where the console is
then assigned to a door triggering this input will then
trigger the door to operate for the programmed time
thus allowing access.
Log Egress Events
There can be many Egress events per day on an access
control system which can clutter the history log over
time. If you enable the Log Egress Events option then the
egress events are recorded into the history log for later
review.
Devices > Keypads & Readers >
Indicator Options
MENU 6-1-5
1 Extinguish N
2 Greetings Y
3 Display Temperature N
4 Display Area Icons N
5 Trouble Alert Beeps Y
6 Entry Exit Warning Y
7 Part Exit Warning N
8 Chime Tone Y
This menu allows you to program various options for
each LAN keypad, LAN reader or LAN fingerprint reader.
Keypads that have an in-built proximity reader, the
parameters set when selecting the keypad is common for
both the keypad and in-built reader.
1) Press [MENU] + [6] + [1] + [5] and use the up and
down arrows to highlight the keypad in the list
then press [OK].
Extinguish
Greetings
Display Temperature
Press  OK ON OFF MENU

Table of Contents

Other manuals for Bosch Solution 6000-IP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 6000-IP and is the answer not in the manual?

Bosch Solution 6000-IP Specifications

General IconGeneral
Event LogYes
Areas1
Partitions1
Outputs2
CommunicationIP, GSM
Mobile AppYes
AutomationYes
System TypeHybrid
Battery BackupYes
KeypadsUp to 8

Related product manuals