Solution 6000-IP
Installation Manual Device Programming
10-3
Bosch Security Systems 10/22 BLCC615I
Devices > Commands >
Keypad Backlight
-
MENU 6-0-9
This menu allows you to adjust the brightness of the
backlight on the keypad’s LCD display. Each keypad can
be adjusted separately to suit the customers needs.
1) Press [MENU] + [6] + [0] + [9] and use the up and
down arrows to highlight the keypad in the list
then press [OK].
L
Keypad 001 Backlight
Press
SAVE
OK
to
H
2) Use the arrow keys to set the required backlight
level. Each time a key is pressed the backlight will
adjust to the new level. When finished press [OK].
KEYPAD & READER OPTIONS
Devices > Keypads & Readers >
Name
-
MENU 6-1-0
K e y p a d 1 N a m e
This menu allows you to program the name or location
description of the keypad or LAN reader.
1) Press [MENU] + [6] + [1] + [0] and select the keypad
or LAN reader from the list and press [OK].
Name Kp1
Keypad 1 Name
Press  OK to SAVE
2) Use the arrow and number keys to move and
change text. When the Reader Name is complete,
press [OK]. At any time you can press the [OFF] key
to clear the text from the current cursor position to
the end of the line.
i
Note
See Alpha Text Programming in Section 4 -
Programming Overview for further detail on entering
alpha text.
Devices > Keypads & Readers >
Area Options
MENU 6-1-2
1 All On Arming Allowed Y
2 Part On Arming Allowed Y
3 Disarming Allowed Y
4 Single Button Control Y
5 All User Areas N
6 Zero Exit Time N
7 PIN To Change Area N
8 Home Area Only N
1) Press [MENU] + [6] + [1] + [2] and select the keypad
or LAN reader from the list then press [OK].
2) Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
All On Arming Allowed
Part On Arming Allowed
Disarming Allowed
Press  OK ON OFF MENU
3) Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.

Table of Contents

Other manuals for Bosch Solution 6000-IP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 6000-IP and is the answer not in the manual?

Bosch Solution 6000-IP Specifications

General IconGeneral
Event LogYes
Areas1
Partitions1
Outputs2
CommunicationIP, GSM
Mobile AppYes
AutomationYes
System TypeHybrid
Battery BackupYes
KeypadsUp to 8

Related product manuals