OUTPUT TESTING
Outputs > Output Testing >
External Siren Test
-
MENU 4-9-0
This menu allows you to test the operation of any output
programmed as event type 36 (External Audible) or Event
Type 39 (Fire Alarm) for 5 seconds.
1) Enter [MENU] + [4] + [9] + [0] and select the area
you want to test the external sirens in from the list
then press [OK].
A1 Security System
A2 Area 2 Name
A3 Area 3 Name
Press OK or MENU
2) Any outputs programmed for event type 36 or 39 in
the chosen area will now operate. The keypad will
display the following during the siren test.
External Audible Testing
Press any key to abort
Press OK or MENU
3) When the siren test is complete, the keypad will
display the following:
Testing Complete. Press
OK to continue
Press OK or MENU
4) Press [OK] to exit.
Outputs > Output Testing >
Internal Siren Test
-
MENU 4-9-1
This menu allows you to test any output programmed
as event type 37 (Internal Audible) or event type 39 (Fire
Alarm) for 5 seconds.
1) Enter [MENU] + [4] + [9] + [1] and select the area
you want to test the internal sirens in from the list
then press [OK].
A1 Security System
A2 Area 2 Name
A3 Area 3 Name
Press OK or MENU
2) Any outputs programmed for event type 37 or 39 in
the chosen area will now operate. The keypad will
display the following during the siren test.
Internal Audible Testing
Press any key to abort
Press OK or MENU
3) When the bell test is complete, the keypad will
display the testing complete message.
Testing Complete. Press
OK to continue
Press OK or MENU
4) Press [OK] to exit.