82
MicroDock II
User Manual
Problem Possible Cause Solution
The docking module does not recognize the
detector.
Detector is deactivated. Activate the detector.
Detector does not have IR communication
capabilities.
Refer to the label located on the back of the
detector for IR capabilities.
Firmware of the detector requires an
update.
Contact BW Technologies by Honeywell
.
Base station is currently attempting to
establish communication with the detector.
Wait approximately 30 seconds.
Docking module is not initialized to the cor-
rect number.
Re-initialize the docking module. Refer to
Adding Another Docking Module
.
Detector and/or base station are damaged
or defective.
Contact BW Technologies by Honeywell
.
There is an audible beep but no charge
(GasAlertMicro and GasAlertMicro
5/PID/IR docking modules).
Battery is above or below the operating
temperature 50°F–95°F (10°C–35°C).
Allow the battery pack time to adjust to the
specified operating temperature (approxi-
mately 60 minutes).
Severely depleted battery.
Charge (2–4 hours) or replace old battery
with new battery. If problem persists, con-
tact BW Technologies by Honeywell
.
Damaged or defective battery pack. Contact BW Technologies by Honeywell
.