Model 201 Installation & Technical
8400-M117-O1 Rev D
Page 130
dYtr= (Dynamic Trim)
This setting controls whether the 201 Admix application will
dynamically adjust the Trim value based on overshoot/undershoot
of each fill. This can be used to ‘learn’ the proper trim value.
Once a trim value has been ‘learned’, which usually takes
between 3 and 10 filling cycles, it is recommended to turn off
dynamic trim..
NOTE: If the DFC Mode is set to “Off” then this setting is not
applicable.
Press the F3/ key to show the current setting. If the setting
displayed is acceptable, press the F3/ key again to save it.
Otherwise, use the F2/ and F1/ keys to enter a new setting
and then press the F3/ key to save it.
AUtod= (Auto Dump)
This setting controls whether the 201 Admix will automatically
discharge after filling or waits for input from the operator or other
controlling system..
NOTE: If the DFC Mode is set to “Off” then this setting is not
applicable.
Press the F3/ key to show the current setting. If the setting
displayed is acceptable, press the F3/ key again to save it.
Otherwise, use the F2/ key to toggle to a new setting and then
press the F3/ key to save it. Allowable settings are:
no
no (Manual Discharge)
YES
YES (Auto Discharge)