Model 201 Installation & Technical
8400-M117-O1 Rev D
- Weight-On-Demand
If Weight-On-Demand has been selected, the 201 will respond to a weight
request (ENQ).
The host device (computer) sends:
ENQ - (hex 05)
The 201 will respond:
<s><xxxxxx><d><uu><m><cc><cr>
Where:
"-" = negative
" " (blank) = positive
Added to string if enabled in setup
OC = overcap
CZ = center of zero
MO = motion
ee = weight not currently being
displayed
drnd - Weight-On-Demand (SMA Format)
If Weight-On-Demand has been selected, the 201 will respond to an SMA
weight request.
The host device (computer) sends:
<LF>W<CR>
The 201 will respond:
<lf><s><r><n><m><f><xxxxxx.xxx><uuu><cr>
NOTE: The Weight-On-Demand (SMA Format) is the same as the SMA
Continuous Output Format. Refer to the description of the data
on the next page.