Model 201 Installation & Technical
8400-M117-O1 Rev D
Page 73
 - SMA Continuous Output Format
If SMA is selected, the data will be transmitted in the following format:
<lf><s><r><n><m><f><xxxxxx.xxx><uuu><cr>
Where:
lf =
Line Feed
s =
Flags
Z= center of Zero
O = Overcap
E = zero Error,
e = weight not currently being
displayed
r =
Range
1, 2, 3, ...
n =
Mode
G = Gross, T = Tare, N = Net
m =
Motion
M = Motion,
" "(blank) = no motion
f =
Custom
Custom flag
xxxxxx.xxx =
Weight
Six digits with decimal point
uuu =
Units
lb, kg, oz, g
cr =
Carriage Return
(hex 0D)
 - Computer Output Format
If ComP is selected, the data will be transmitted in the following format:
<s><xxxxxx><d><uu><m><cc><cr>
Where:
s =
Sign
"-" = negative
" " (blank) = positive
xxxxxx.xxx =
Weight
Six digits
d =
Decimal point
Added to string if enabled in setup
uu =
Units
LB, KG, OZ, G
m =
Mode
G = Gross, N = Net
cc =
Weight Status
OC = overcap
CZ = center of zero
MO = motion
ee = weight not currently being
displayed
cr =
Carriage Return
(hex 0D)