Model 201 Installation & Technical
8400-M117-O1 Rev D
Page 81
InP 4= (Digital Input 4)
Press the F3/ key to show the current setting. If the setting displayed is
acceptable, press the F3/ key again to save it. Otherwise, use the
F2/ key to toggle to a new setting and then press the F3/ key to save
it. Allowable settings are:
Selection
Function
off
Off (Digital Input 4 is disabled)
2ero
Zero Scale
tare
Tare
gr-net
Gross/Net
Units
Units
print
Print
dfCSt
Digital Fill Control Start/Pause
dfCdC
Digital Fill Control Discharge
out 1= (Digital Output 1)
Press the F3/ key to show the current setting. If the setting displayed is
acceptable, press the F3/ key again to save it. Otherwise, use the
F2/ key to toggle to a new setting and then press the F3/ key to save
it. Allowable settings are:
Selection
Function
off
Off (Digital Output 1 is disabled)
Under
Check weigh Under
ACCEPT
Check weigh Accept
oEr
Check weigh Over