8545-M838-O1 Rev D 825 Installation & Technical
97
CONFIGURATION, CONT.
Type:
With the Select TCP/IP Server 1 screen displayed, the current setting for the Type:
parameter will be shown. If the setting displayed is acceptable, press the ENTER key to
return to the Select TCP/IP Server screen.
Otherwise, press the SPACE key to step through and select the communication type and
then press the ENTER key to save the new setting and return to the
Select TCP/IP Server screen. Available types are:
SB250
SB250M
SB500
SB500M
SB80
SB200
SB300
SB400
SMA
Computer Fmt
On Demand
iSite
Custom
Setup TCP/IP Server 2
With the Select TCP/IP Server screen displayed, press the 2 key or use the Navigation Keys
to select (highlight) and then press the ENTER key to select Num 2. The display will
change to show the Setup TCP/IP Server 2 screen.
The setup parameters for TCP/IP Server 2 are the same as TCP/IP Server 1. Refer to the
Setup TCP/IP Server 1 parameters.
** Add Server **
With the Select TCP/IP Server screen displayed, press the A key or use the Navigation
Keys to select (highlight) and then press the ENTER key to select ** Add Server **. The
display will change to show the Setup TCP/IP Server 3 screen.
The setup parameters for adding an additional TCP/IP Server are the same as the setup for
TCP/IP Server 1. Refer to the Setup TCP/IP Server 1 parameters.