8545-M838-O1 Rev D 825 Installation & Technical
49
SETUP AND CALIBRATION, CONT.
2. Comm Port 1 Defaults
3. Comm Port 2 Defaults
4. Comm Port 3 Defaults
5. Comm Port 4 Defaults
With the Communication Menu displayed, press the 2, 3, 4 or 5 key or use the Navigation
Keys to select (highlight) the Com port to be configured and then press the ENTER key.
The display will change to show the setup screen for the Com port selected.
Baud:
With the Setup Com port screen displayed the current setting for the Baud: parameter
will be shown. If the setting displayed is acceptable, proceed to the next parameter.
Otherwise, press the SPACE key to step through and select the baud rate and then press
the Down Arrow to advance to the next parameter or press the ENTER key to save the
new setting and return to the previous screen display. Supported Baud rates are:
1200
4800
19200
57600
2400
9600
38400
115200
Parity:
With the Setup Com port 1 screen displayed, the current setting for the Parity:
parameter will be shown. If the setting displayed is acceptable, proceed to the next
parameter.
Otherwise, press the SPACE key to step through and select the parity and then press the
Down Arrow to advance to the next parameter or press the ENTER key to save the
new setting and return to the previous screen. Supported Parity is:
None (No Parity)
Even
Odd
Data Bits:
With the Setup Com port 1 screen displayed, the current setting for the Data Bits:
parameter will be shown. If the setting displayed is acceptable, proceed to the next
parameter.
Otherwise, use the numeric keys to enter the data bits and then press the Down Arrow
to advance to the next parameter or press the ENTER key to save the new setting and
return to the previous screen. Supported Data Bits are 7 or 8.
Stop Bits:
With the Setup Com port 1 screen displayed, the current setting for the Stop Bits:
parameter will be shown. If the setting displayed is acceptable, press the ENTER key or
the Navigation Keys Left Arrow to return to the previous screen.
Otherwise, use the numeric keys to enter the stop bits and then press the ENTER key to
save the new setting and return to the previous screen. Supported Stop Bits are 1 or 2.