7-MAINTENANCE
Hydraulicreservoirbreather
Changethebreatherforthehydraulicreservoirafter1000
hoursofoperation.
1.Cleantheareasaroundthetopofthehydraulicreser-
voir,includingthebreatherandthehydraulictubing
abovethebreather.
RCPH10TLB427AAF1
2.Slowlyremovethellcapforthehydraulicreservoir.
3.Afterpressureisreleased,replacethereservoircap.
RCPH10TLB428AAF2
4.Removeanddiscardthebreatherfromthehydraulic
reservoirtank.Turncounter-clockwisetounscrew.
5.Ensuretheo-ringisseatedcorrectlyinthenew
breatherandinstallthenewbreatherinthehydraulic
reservoirtank.Turnclockwisetotighten.Hand
tightenortightentoapproximately10N·m(7.4lbft).
RCPH10TLB427AAF3
7-77