CG Drives & Automation,01-5326-01r5 175
Communication information
AnOut 1 Setup [532]
Preset scaling and offset of the output configuration.
Communication information
Fig. 131
AnOut1 Advanced [533]
With the functions in the AnOut1 Advanced menu, the
output can be completely defined according to the
application needs. The menus will automatically be adapted
to “mA” or “V”, according to the selection in AnOut1
Setup [532]”.
AnOut1 Min [5331]
This parameter is automatically displayed if User mA or
User V is selected in menu “AnOut 1 Setup [532]”. The
menu will automatically adapt to current or voltage setting
according to the selected setup. Only visible if [532] = User
mA/V.
Communication information
Modbus Instance no/DeviceNet no: 43251
Profibus slot/index 169/155
EtherCAT and CANopen index (hex) 4cb3
Profinet IO index 19635
Fieldbus format UInt
Modbus format UInt
532 AnOut1 Setup
Default: 4-20mA
4–20mA 0
The current output has a fixed threshold
(Live Zero) of 4 mA and controls the full
range for the output signal. See Fig.
128.
0–20mA 1
Normal full current scale configuration of
the output that controls the full range for
the output signal. See Fig. 127.
User mA 2
The scale of the current controlled
output that controls the full range for the
output signal. Can be defined by the
advanced AnOut Min and AnOut Max
menus.
User Bipol
mA
3
Sets the output for a bipolar current
output, where the scale controls the
range for the output signal. Scale can be
defined in advanced menu AnOut Bipol.
0-10V 4
Normal full voltage scale configuration of
the output that controls the full range for
the output signal. See Fig. 127.
2–10V 5
The voltage output has a fixed threshold
(Live Zero) of 2 V and controls the full
range for the output signal. See Fig.
128.
User V 6
The scale of the voltage controlled
output that controls the full range for the
output signal. Can be defined by the
advanced AnOut Min and AnOut Max
menus.
User Bipol
V
7
Sets the output for a bipolar voltage
output, where the scale controls the
range for the output signal. Scale can be
defined in advanced menu AnOut Bipol.
Modbus Instance no/DeviceNet no: 43252
Profibus slot/index 169/156
EtherCAT and CANopen index (hex) 4cb4
Profinet IO index 19636
Fieldbus format UInt
Modbus format UInt
533 AnOut 1 Adv
5331 AnOut 1 Min
Default: 4 mA
Range: 0.00 – 20.00 mA, 0 – 10.00 V
Modbus Instance no/DeviceNet no: 43253
Profibus slot/index 169/157
EtherCAT and CANopen index (hex) 4cb5
Profinet IO index 19637
Fieldbus format
Long, 1=0.01 V,
0.01 mA
Modbus format EInt
AC drive 1
Master
AC drive 2
Slave
Ref.
AnOut
Ref.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CG Emotron VFX Series and is the answer not in the manual?

CG Emotron VFX Series Specifications

General IconGeneral
BrandCG
ModelEmotron VFX Series
CategoryController
LanguageEnglish

Related product manuals