9 - DIAGNOSTICS
DIAGNOSTICA (ME)
ME2000S - User Manual
127 - 133
CODE MESSAGE DESCRIPTION SOLUTION
88 Motor punch (Driver command)
Punch motor driver error
Turn o󰀨 the machine and wait a few
seconds. Verify if a plate remains
jammed. Start and re-initialize the
machine. If the error still occurs,
contact Service Support.
89 Motor punch (Driver step mode)
90
Motor punch (Driver under-
voltage)
91
Motor punch (Driver under-voltage
ADC)
92 Motor punch (Driver over-current)
93 Motor punch (Driver thermal)
94
Motor punch (Zero: First zero
active not detected)
Error during the reset of the
Punch motor
Check the “PUNCH-motor” sensor
and/or switch o󰀨 the machine and
check the motor movement. If the
error is still present, contact technical
support.
95
Motor punch (Zero: Zero not
active not detected)
96
Motor punch (Zero: Second zero
active not detected)
97
Motor punch (Zero: First zero not
active not detected)
98
Motor punch (Zero: Di󰀨erence in
steps is too high)
99 Motor punch (Zero: Motor busy) Internal error
Turn o󰀨 the machine and wait a few
seconds. Verify if a plate remains
jammed. Start and re-initialize the
machine. If the error still occurs,
contact Service Support.
100 Motor loader (Generic)
Loader motor driver error
Turn o󰀨 the machine and wait a few
seconds. Verify if a plate remains
jammed. Start and re-initialize the
machine. If the error still occurs,
contact Service Support.
101 Motor loader (Driver generic)
102 Motor loader (Driver high Z)