5 - INSTALLATION
INSTALLAZIONE (ME)
ME2000S - User Manual
44 - 133
5.3 Installation precautions and warnings
Make sure that the power supply is compatible with the specications indicated on the data plate.
WARNING
Before switching on the machine, make sure that all cables have been connected correctly.
5.3.1 Fuse replacement
If unusual conditions or failures occur, the delayed safety fuse may cut o the power.
To replace the safety fuse:
1) Remove the power plug.
2) Insert the tip of a athead screwdriver into the bottom of the plug opening.
3) Carefully prise the fuse holder upwards until it can be removed by hand.
4) Remove the damaged fuse.
5) Replace the fuse with a new one.
6) Put the fuse holder back in place.
WARNING
ONLY REPLACE FUSES WITH THOSE OF THE SAME TYPE AND RATING.
Europe: IEC 60127 approved
America - UL248-1 and UL248-14 approved