184
Enter Setup
2564 Barcode Scanner User Guide
*Disable AIM Code ID
After applying AIM Code ID, three characters are added in front of the output data. ] is
always the first character. The second (Character) and third (Modifier Character) may
vary depending on symbologies. Please refer to the table below.
Symbology
Character
Modifier Character
Codabar
F
0: Standard Codabar symbol. No special processing.
Code 11
H
0: Single modulo 11 check character validated and transmitted
1: Two modulo 11 check characters validated and transmitted
3: Check characters validated but not transmitted
?: No check character validation
Code 39
A
0: No check character validation nor full ASCII processing. All data
transmitted as decoded.
1: Modulo 43 check character validated and transmitted
3: Modulo 43 check character validated but not transmitted
4: Full ASCII character conversion performed. No check character
validation.
5: Full ASCII character conversion performed. Modulo 43 check
character validated and transmitted.
7: Full ASCII character conversion performed. Modulo 43 check
character validated but not transmitted.
Code 93
G
No options specified. Always transmit 0.
Code 128
C
0: Standard data packet. No FNC1 in first or second symbol character
position after start character.
1: EAN/UCC-128 data packet. FNC1 in first symbol character position
after start character.
2: FNC1 in second symbol character position after start character.
4: Concatenation according to International Society for Blood
Transfusion specifications has been performed. Concatenated data
follows.
GS1 DataBar
Family
e
No option specified at this time. Always transmit 0. GS1 DataBar and
GS1 DataBar Limited transmit with an Application Identifier “01”.
Interleaved
25
I
0: No check character validation
1: Modulo 10 symbol check character validated and transmitted
3: Modulo 10 symbol check character validated but not transmitted
MSI
M
0: Modulo 10 symbol check character validated and transmitted
1: Modulo 10 symbol check character validated but not transmitted
Matrix 25
X
No options specified. Always transmit 0.